fix: add named port 'http' to vin-decoder Service and container for ServiceMonitor scraping #230

Merged
AI-Manager merged 1 commits from feature/fix-vin-decoder-servicemonitor-port into main 2026-06-07 05:06:43 +00:00

1 Commits

Author SHA1 Message Date
AI-Agent cc7172d563 fix: add named port 'http' to vin-decoder Service and container for ServiceMonitor compatibility
Validate Flux manifests / kustomize-build (pull_request) Failing after 20s
The ServiceMonitor at flux/vin-decoder/servicemonitor.yaml references port
by name ('http'), but the Service had anonymous port 80 -> 3000 and the
container had no named port. Prometheus ServiceMonitor port matching requires
the port name to match between the Service and the ServiceMonitor spec.

Adds:
- name: http to the containerPort (port 3000)
- name: http to the Service port (port 80 -> targetPort 3000)

This allows the kube-prometheus-stack ServiceMonitor to correctly scrape
/metrics from vin-decoder pods.

Closes leeworks-agents/api-company#174
2026-06-07 05:06:10 +00:00